Line Drawings

Line Drawings are a tool used by contractors and engineers to be able to include a steel bolted water tank into any project. If the plans call for any custom features they can be added to the line drawing so everyone in the development look from building to construction knows exactly what the finished product needs to include. Ate SteelCore Tank we value the great relationships we have with 1000’s of water engineers, city managers, municipalities and any government agency bound by a strict regulatory standard, which is why we have provided the professional firms and governments with line drawings of all our steel bolted tanks so they can easily include them into any current or upcoming projects. Each line drawing includes an aerial view, side view with elevation specifications and then detailed dimensions of each element of the tank from top to bottom.

To serve our clients and their advisors better we have created these line drawings and can also include any needed appurtenance that is required for any job-specific safety requirements. As a premier manufacturer of corrugated bolted steel tanks, we serve our clients first and always willing to create specifications on any custom tank application needed. Check out our large display of line drawings for the corresponding tank broken down by size by gallons.

GallonsNominal
Gallons
RoofPart –
Model
DescriptionDiameterEve HeightOverall
Height Ft.
Freeboard
in inches
Freeboard
in Feet
WeightLine Drawings
70072230º flat panelSCT-601-FPCorrugated Steel Tank6.193.55.040.31,776Line Drawing
1,0001,51830º flat panelSCT-602-FPCorrugated Steel Tank6.197.18.540.31,994Line Drawing
1,5001,62430º flat panelSCT-901-FPCorrugated Steel Tank9.283.55.940.32,001Line Drawing
2,0002,31530º flat panelSCT-603-FPCorrugated Steel Tank6.1910.612.040.32,113Line Drawing
3,0002,88630º v ribSCT-1201-VRCorrugated Steel Tank12.373.56.840.32,188Line Drawing
3,0002,88610º low v ribSCT-1201-LVRCorrugated Steel Tank12.373.55′-0″ (+/-)40.32,188Line Drawing
3,5003,41630º flat panelSCT-902-FPCorrugated Steel Tank9.287.19.440.32,188Line Drawing
4,0003,90830º flat panelSCT-605-FPCorrugated Steel Tank6.1917.719.140.32,451Line Drawing
4,5004,51030º v ribSCT-1501-VRCorrugated Steel Tank15.473.57.740.32,451Line Drawing
4,5004,51010º low v ribSCT-1501-LVRCorrugated Steel Tank15.473.55′-2″ (+/-)40.32,451Line Drawing
5,0004,70430º flat panelSCT-606-FPCorrugated Steel Tank6.1921.222.740.32,619Line Drawing
5,0005,20830º flat panelSCT-903-FPCorrugated Steel Tank9.2810.613.040.32,376Line Drawing
6,0006,07230º v ribSCT-1202-VRCorrugated Steel Tank12.377.110.340.32,413Line Drawing
6,0006,07210º low v ribSCT-1202-LVRCorrugated Steel Tank12.377.18′-6″(+/-)40.32,413Line Drawing
6,5006,49430º v ribSCT-1801-VRCorrugated Steel Tank18.563.58.640.32,630Line Drawing
6,5006,49410º low v ribSCT-1801-LVRCorrugated Steel Tank18.563.55′-3″(+/-)40.32,630Line Drawing
7,0007,00030º flat panelSCT-904-FPCorrugated Steel Tank9.2814.216.540.32,563Line Drawing
8,0008,79230º flat panelSCT-905-FPCorrugated Steel Tank9.2817.720.040.32,751Line Drawing
8,0008,83930º v ribSCT-2101-VRCorrugated Steel Tank21.653.59.540.32,841Line Drawing
8,0008,83910º low v ribSCT-2101-LVRCorrugated Steel Tank21.653.55′-5″(+/-)40.32,841Line Drawing
9,0009,25930º v ribSCT-1203-VRCorrugated Steel Tank12.3710.613.940.32,638Line Drawing
9,0009,25910º low v ribSCT-1203-LVRCorrugated Steel Tank12.3710.611′-10″(+/-)40.32,638Line Drawing
10,0009,48830º v ribSCT-1502-VRCorrugated Steel Tank15.477.111.340.32,713Line Drawing
10,0009,48810º low v ribSCT-1502-LVRCorrugated Steel Tank15.477.18′-7″ (+/-)40.32,713Line Drawing
10,00010,58530º flat panelSCT-906-FPCorrugated Steel Tank9.2821.223.640.32,938Line Drawing
11,00011,54530º v ribSCT-2401-VRCorrugated Steel Tank24.753.510.540.33,224Line Drawing
11,00011.54510º low v ribSCT-2401-LVRCorrugated Steel Tank24.753.55′-9″(+/-)40.33,224Line Drawing
12,00012,44530º v ribSCT-1204-VRCorrugated Steel Tank12.3714.217.440.32,863Line Drawing
12,00012,44510º low v ribSCT-1204-LVRCorrugated Steel Tank12.3714.215′-5″(+/-)40.32,863Line Drawing
13,00013,66330º v ribSCT-1802-VRCorrugated Steel Tank18.567.112.240.32,967Line Drawing
13,00013,66310º low v ribSCT-1802-LVRCorrugated Steel Tank18.567.18′-9″(+/-)40.32,967Line Drawing
14,00014,46730º v ribSCT-1503-VRCorrugated Steel Tank15.4710.614.840.32.976Line Drawing
14,00014,46710º low v ribSCT-1503-LVRCorrugated Steel Tank15.4710.612′-2″(+/-)40.32,976Line Drawing
14,00014,61230º v ribSCT-2701-VRCorrugated Steel Tank27.843.511.340.33,836Line Drawing
14,00014,61210º low v ribSCT-2701-LVRCorrugated Steel Tank27.843.511.340.33,836Line Drawing
15,00015,63130º v ribSCT-1205-VRCorrugated Steel Tank12.3717.721.040.33,088Line Drawing
15,00015,63110º low v ribSCT-1205-LVRCorrugated Steel Tank12.3717.719′-0″(+/-)40.33,088Line Drawing
18,00018,03930º v ribSCT-3001-VRCorrugated Steel Tank30.943.512.240.34,194Line Drawing
18,00018,03910º low v ribSCT-3001-LVRCorrugated Steel Tank30.943.56′-2″(+/-)40.34,194Line Drawing
18,50018,59730º v ribSCT-2102-VRCorrugated Steel Tank21.657.113.140.33,235Line Drawing
18,50018,59710º low v ribSCT-2102-LVRCorrugated Steel Tank21.657.19′-0″(+/-)40.33,235Line Drawing
19,00018,81730º v ribSCT-1206-VRCorrugated Steel Tank12.3721.224.540.33,578Line Drawing
19,00018,81710º low v ribSCT-1206-LVRCorrugated Steel Tank12.3721.222′-6″(+/-)40.33,578Line Drawing
19,50019,44530º v ribSCT-1504-VRCorrugated Steel Tank15.4714.218.340.32,847Line Drawing
19,50019,44510º low v ribSCT-1504-LVRCorrugated Steel Tank15.4714.215′-7″ (+/-)40.32,847Line Drawing
20,00020,83230º v ribSCT-1803-VRCorrugated Steel Tank18.5610.615.740.33,305Line Drawing
20,00020,83210º low v ribSCT-1803-LVRCorrugated Steel Tank18.5610.612′-3″ (+/-)40.33,305Line Drawing
21,00021,82830º v ribSCT-3401-VRCorrugated Steel Tank34.033.513.140.34,505Line Drawing
21,00021,82810º low v ribSCT-3401-LVRCorrugated Steel Tank34.033.56′-0″(+/-)40.34,505Line Drawing
25,00024,29030º v ribSCT-2402-VRCorrugated Steel Tank24.757.114.040.33,674Line Drawing
25,00024,29010º low v ribSCT-2402-LVRCorrugated Steel Tank24.757.19′-4″(+/-)40.33,674Line Drawing
25,00024,42330º v ribSCT-1505-VRCorrugated Steel Tank15.4717.721.940.33,305Line Drawing
25,00024,42310º low v ribSCT-1505-LVRCorrugated Steel Tank15.4717.719′-3″(+/-)40.33,305Line Drawing
26,00025,97730º v ribSCT-3701-VRCorrugated Steel Tank37.13.514.340.34,920Line Drawing
26,00025,97710º low v ribSCT-3701-LVRCorrugated Steel Tank37.13.56′-10″(+/-)40.34,920Line Drawing
26,00028,00130º v ribSCT-1804-VRCorrugated Steel Tank18.614.219.240.33,440Line Drawing
28,00028,00110º low v ribSCT-1804-LVRCorrugated Steel Tank18.614.215′-10″(+/-)40.33,440Line Drawing
28,00028,35530º v ribSCT-2103-VRCorrugated Steel Tank21.710.616.640.33,629Line Drawing
28,00028,35510º low v ribSCT-2103-LVRCorrugated Steel Tank21.710.612′-7″(+/-)40.33,629Line Drawing
30,00029,40230º v ribSCT-1506-VRCorrugated Steel Tank15.521.225.440.33,886Line Drawing
30,00029,40210º low v ribSCT-1506-LVRCorrugated Steel Tank15.521.222′-8″(+/-)40.33,886Line Drawing
30,00030,74230º v ribSCT-2702-VRCorrugated Steel Tank27.87.114.840.34,356Line Drawing
30,00030,74210º low v ribSCT-2702-LVRCorrugated Steel Tank27.87.114.840.34,356Line Drawing
35,00035,17030º v ribSCT-1805-VRCorrugated Steel Tank18.617.722.840.33,995Line Drawing
35,00035,17010º low v ribSCT-1805-LVRCorrugated Steel Tank18.617.719′-5″(+/-)40.33,995Line Drawing
35,00035,35730º v ribSCT-4301-VRCorrugated Steel Tank43.33.516.540.37,162Line Drawing
35,00035,35710º low v ribSCT-4301-LVRCorrugated Steel Tank43.33.57′-4″(+/-)40.37,162Line Drawing
37,00037,03530º v ribSCT-2403-VRCorrugated Steel Tank24.710.617.540.34,124Line Drawing
37,00037,03510º low v ribSCT-2403-LVRCorrugated Steel Tank24.710.612′-10″(+/-)40.34,124Line Drawing
38,00037,95330º v ribSCT-3002-VRCorrugated Steel Tank30.97.115.840.34,834Line Drawing
38,00037,95310º low v ribSCT-3002-LVRCorrugated Steel Tank30.97.19′-10″(+/-)40.34,834Line Drawing
38,00038,11230º v ribSCT-2104-VRCorrugated Steel Tank21.714.220.240.34,033Line Drawing
38,00038,11210º low v ribSCT-2104-LVRCorrugated Steel Tank21.714.216′-2″(+/-)40.34,033Line Drawing
43,00042,33930º v ribSCT-1806-VRCorrugated Steel Tank18.621.226.340.34,692Line Drawing
43,00042,33910º low v ribSCT-1806-LVRCorrugated Steel Tank18.621.222′-10″(+/-)40.34,692Line Drawing
44,00044,02530º J ribSCT-5501-JRCorrugated Steel Tank55.73.518.540.317,633Line Drawing
46,00045,92330º v ribSCT-3402-VRCorrugated Steel Tank34.07.116.740.35,397Line Drawing
46,00045,92310º low v ribSCT-3402-LVRCorrugated Steel Tank34.07.110′-0″‘(+/-)40.35,397Line Drawing
46,00046,18130º v ribSCT-4901-VRCorrugated Steel Tank49.53.518.240.39,566Line Drawing
46,00046,18110º low J ribSCT-5501-LJRCorrugated Steel Tank49.53.57′-10″(+/-)40.39,566Line Drawing
46,00046,18110º low v ribSCT-4901-LVRCorrugated Steel Tank49.53.57′-10″(+/-)40.39,566Line Drawing
47,00046,87230º v ribSCT-2703-VRCorrugated Steel Tank27.810.618.440.34,876Line Drawing
47,00046,87210º low v ribSCT-2703-LVRCorrugated Steel Tank27.810.618.440.34,876Line Drawing
48,00047,87030º v ribSCT-2105-VRCorrugated Steel Tank21.717.723.740.34,835Line Drawing
48,00047,87010º low v ribSCT-2105-LVRCorrugated Steel Tank21.717.719′-9″(+/-)40.34,835Line Drawing
50,00049,77930º v ribSCT-2404-VRCorrugated Steel Tank24.714.221.140.34,735Line Drawing
50,00049,77910º low v ribSCT-2404-LVRCorrugated Steel Tank24.714.216′-4″(+/-)40.34,735Line Drawing
50,00054,35430º J ribSCT-6101-JRCorrugated Steel Tank61.93.520.340.3Line Drawing
50,00054,35410º low J ribSCT-6101-LJRCorrugated Steel Tank61.93.59′-0″(+/-)40.3Line Drawing
50,00054,65230º v ribSCT-3702-VRCorrugated Steel Tank37.17.117.840.36,045Line Drawing
50,00054,65210º low v ribSCT-3702-LVRCorrugated Steel Tank37.17.110′-5″(+/-)40.36,045Line Drawing
55,00057,62730º v ribSCT-2106-VRCorrugated Steel Tank21.721.227.240.35,640Line Drawing
55,00057,62710º low v ribSCT-2106-LVRCorrugated Steel Tank21.721.223′-2″(+/-)40.35,640Line Drawing
55,00057,86630º v ribSCT-3003-VRCorrugated Steel Tank30.910.619.340.35,474Line Drawing
55,00057,86610º low v ribSCT-3003-LVRCorrugated Steel Tank30.910.613′-4″(+/-)40.35,474Line Drawing
60,00062,52430º v ribSCT-2405-VRCorrugated Steel Tank24.717.724.640.35,663Line Drawing
60,00062,52410º low v ribSCT-2405-LVRCorrugated Steel Tank24.717.719′-11″(+/-)40.35,663Line Drawing
60,00063,00230º v ribSCT-2704-VRCorrugated Steel Tank27.814.221.940.35,489Line Drawing
60,00063,00210º low v ribSCT-2704-LVRCorrugated Steel Tank27.814.221.940.35,489Line Drawing
70,00070,01830º v ribSCT-3403-VRCorrugated Steel Tank34.010.620.240.36,290Line Drawing
70,00070,01810º low v ribSCT-3403-LVRCorrugated Steel Tank34.010.613′-8″(+/-)40.36,290Line Drawing
70,00074,38830º v ribSCT-4302-VRCorrugated Steel Tank43.37.120.040.38,467Line Drawing
70,00074,38810º low v ribSCT-4302-LVRCorrugated Steel Tank43.37.110′-11″(+/-)40.38,467Line Drawing
75,00075,26830º v ribSCT-2406-VRCorrugated Steel Tank24.721.228.240.36,585Line Drawing
75,00075,26810º low v ribSCT-2406-LVRCorrugated Steel Tank24.721.223′-5″(+/-)40.36,585Line Drawing
75,00077,78030º v ribSCT-3004-VRCorrugated Steel Tank30.914.222.840.36,540Line Drawing
75,00077,78010º low v ribSCT-3004-LVRCorrugated Steel Tank30.914.216′-10″(+/-)40.36,540Line Drawing
75,00078,26730º J ribSCT-7401-JRCorrugated Steel Tank74.23.523.940.3Line Drawing
75,00078,26710º low J ribSCT-7401-LJRCorrugated Steel Tank74.23.540.3Line Drawing
80,00079,13230º v ribSCT-2705-VRCorrugated Steel Tank27.817.725.540.36,533Line Drawing
80,00079,13210º low v ribSCT-2705-LVRCorrugated Steel Tank27.817.725.540.36,533Line Drawing
80,00083,32830º v ribSCT-3703-VRCorrugated Steel Tank37.110.621.440.37,170Line Drawing
80,00083,32810º low v ribSCT-3703-LVRCorrugated Steel Tank37.110.613′-11″(+/-)40.37,170Line Drawing
90,00094,11430º v ribSCT-3404-VRCorrugated Steel Tank34.014.223.740.37,313Line Drawing
90,00094,11410º low v ribSCT-3404-LVRCorrugated Steel Tank34.014.217′-3″(+/-)40.37,313Line Drawing
95,00095,26230º v ribSCT-2706-VRCorrugated Steel Tank27.821.229.040.37,805Line Drawing
95,00095,26210º low v ribSCT-2706-LVRCorrugated Steel Tank27.821.229.040.37,805Line Drawing
95,00097,15930º v ribSCT-4902-VRCorrugated Steel Tank49.57.121.840.310,991Line Drawing
95,00097,15910º low v ribSCT-4902-LVRCorrugated Steel Tank49.57.111′-5″(+/-)40.310,991Line Drawing
95,00097,15910º low J ribSCT-5502-LJRCorrugated Steel Tank49.57.111′-5″(+/-)40.310,991Line Drawing
95,00097,69330º v ribSCT-3005-VRCorrugated Steel Tank30.917.726.440.37,694Line Drawing
95,00097,69310º low v ribSCT-3005-LVRCorrugated Steel Tank30.917.720′-5″(+/-)40.37,694Line Drawing
100,000112,00330º v ribSCT-3704-VRCorrugated Steel Tank37.114.224.940.38,263Line Drawing
100,000112,00310º low v ribSCT-3704-LVRCorrugated Steel Tank37.114.217′-6″(+/-)40.38,263Line Drawing
100,000113,41830º v ribSCT-4303-VRCorrugated Steel Tank43.310.623.540.39,772Line Drawing
100,000113,41810º low v ribSCT-4303-LVRCorrugated Steel Tank43.310.614′-5″(+/-)40.39,772Line Drawing
100,000117,60730º v ribSCT-3006-VRCorrugated Steel Tank30.921.229.940.39,111Line Drawing
100,000117,60710º low v ribSCT-3006-LVRCorrugated Steel Tank30.921.224′-0″(+/-)40.39,111Line Drawing
100,000118,20930º v ribSCT-3405-VRCorrugated Steel Tank34.017.727.340.38,847Line Drawing
100,000118,20910º low v ribSCT-3405-LVRCorrugated Steel Tank34.017.720′-10″(+/-)40.38,847Line Drawing
130,000134,00610º low J ribSCT-6102-LJRCorrugated Steel Tank61.97.140.3Line Drawing
140,000140,67930º v ribSCT-3705-VRCorrugated Steel Tank37.117.728.540.39,951Line Drawing
140,000140,67910º low v ribSCT-3705-LVRCorrugated Steel Tank37.117.721′-1″(+/-)40.39,951Line Drawing
140,000142,30430º v ribSCT-3406-VRCorrugated Steel Tank34.021.230.840.310,358Line Drawing
140,000142,30410º low v ribSCT-3406-LVRCorrugated Steel Tank34.021.224′-4″(+/-)40.310,358Line Drawing
145,000148,13830º v ribSCT-4903-VRCorrugated Steel Tank49.510.625.340.312,416Line Drawing
145,000148,13810º low J ribSCT-5503-LJRCorrugated Steel Tank49.510.614′-11″(+/-)40.312,416Line Drawing
145,000148,13810º low v ribSCT-4903-LVRCorrugated Steel Tank49.510.614′-11″(+/-)40.312,416Line Drawing
150,000152,44930º v ribSCT-4304-VRCorrugated Steel Tank43.314.227.140.311,069Line Drawing
150,000152,44910º low v ribSCT-4304-LVRCorrugated Steel Tank43.314.218′-0″(+/-)40.311,069Line Drawing
170,000169,35430º v ribSCT-3706-VRCorrugated Steel Tank37.121.232.040.311,848Line Drawing
170,000169,35410º low v ribSCT-3706-LVRCorrugated Steel Tank37.121.224′-7″(+/-)40.311,848Line Drawing
170,000173,06530º J ribSCT-5503-JRCorrugated Steel Tank55.710.625.640.321,954Line Drawing
190,000191,47930º v ribSCT-4305-VRCorrugated Steel Tank43.317.730.640.313,026Line Drawing
190,000191,47910º low v ribSCT-4305-LVRCorrugated Steel Tank43.317.721′-7″(+/-)40.313,026Line Drawing
190,000192,96910º low J ribSCT-7402-LJRCorrugated Steel Tank74.27.140.3Line Drawing
190,000192,96930º J ribSCT-7402-JRCorrugated Steel Tank74.27.127.440.3Line Drawing
200,000199,11730º v ribSCT-4904-VRCorrugated Steel Tank49.514.228.840.314,330Line Drawing
200,000199,11710º low J ribSCT-5504-LJRCorrugated Steel Tank49.514.218′-6″(+/-)40.314,330Line Drawing
200,000199,11710º low v ribSCT-4904-LVRCorrugated Steel Tank49.514.218′-6″(+/-)40.314,330Line Drawing
210,000213,66110º low J ribSCT-6103-LJRCorrugated Steel Tank61.910.616′-1″(+/-)40.3Line Drawing
210,000213,66130º J ribSCT-6103-JRCorrugated Steel Tank61.910.627.440.3Line Drawing
230,000230,51030º v ribSCT-4306-VRCorrugated Steel Tank43.321.234.240.315,237Line Drawing
230,000230,51010º low v ribSCT-4306-LVRCorrugated Steel Tank43.321.225′-1″(+/-)40.315,237Line Drawing
230,000237,58530º J ribSCT-5504-JRCorrugated Steel Tank55.714.229.240.324,226Line Drawing
250,000250,09530º v ribSCT-4905-VRCorrugated Steel Tank49.517.732.440.316,518Line Drawing
250,000250,09510º low v ribSCT-4905-LVRCorrugated Steel Tank49.517.722′-1″(+/-)40.316,518Line Drawing
250,000250,09510º low J ribSCT-5505-LJRCorrugated Steel Tank49.517.722′-1″(+/-)40.316,518Line Drawing
300,000293,31530º J ribSCT-6104-JRCorrugated Steel Tank61.914.230.940.3Line Drawing
300,000293,31510º low J ribSCT-6104-LJRCorrugated Steel Tank61.914.219′-8″(+/-)40.3Line Drawing
300,000301,07430º v ribSCT-4906-VRCorrugated Steel Tank49.521.235.940.319,062Line Drawing
300,000301,07410º low v ribSCT-4906-LVRCorrugated Steel Tank49.521.225′-7″(+/-)40.319,062Line Drawing
300,000301,07410º low J ribSCT-5506-LJRCorrugated Steel Tank49.521.225′-7″(+/-)40.319,062Line Drawing
300,000302,10530º J ribSCT-5505-JRCorrugated Steel Tank55.717.732.740.326,734Line Drawing
300,000307,67130º J ribSCT-7403-JRCorrugated Steel Tank74.210.631.040.3Line Drawing
300,000307,67110º low J ribSCT-7403-LJRCorrugated Steel Tank74.210.640.3Line Drawing
350,000366,62530º J ribSCT-5506-JRCorrugated Steel Tank55.721.236.240.329,501Line Drawing
350,000372,96930º J ribSCT-6105-JRCorrugated Steel Tank61.917.734.540.3Line Drawing
350,000372,96910º low J ribSCT-6105-LJRCorrugated Steel Tank61.917.723′-3″(+/-)40.3Line Drawing
400,000422,37330º J ribSCT-7404-JRCorrugated Steel Tank74.214.234.540.3Line Drawing
400,000422,37310º low J ribSCT-7404-LJRCorrugated Steel Tank74.214.240.3Line Drawing
400,000452,62330º J ribSCT-6106-JRCorrugated Steel Tank61.921.238.040.3Line Drawing
450,000452,62310º low J ribSCT-6106-LJRCorrugated Steel Tank61.921.226-9″(+/-)40.3Line Drawing
500,000537,07530º J ribSCT-7405-JRCorrugated Steel Tank74.217.738.040.3Line Drawing
500,000537,07510º low J ribSCT-7405-LJRCorrugated Steel Tank74.217.740.3Line Drawing
650,000651,77730º J ribSCT-7406-JRCorrugated Steel Tank74.221.241.640.3Line Drawing
650,000651,77710º low J ribSCT-7406-LJRCorrugated Steel Tank74.221.240.3Line Drawing